EasyManuals Logo

Siemens Brodersen MC55 AT User Manual

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #404 background imageLoading...
Page #404 background image
MC55_ATC_V04.00 Page 404 of 475 3/17/06
Confidential / Released
17.5 AT+CMUT Mute control
The AT+CMUT command mutes the microphone input. The command can be used in all audio modes (1 to 6) and
during a voice call only. See AT^SNFS for more details on the various audio modes. As alternative, you can use
the AT^SNFM command.
During an active call, users should be aware that when they switch back and forth between different audio modes
(for example handsfree on/off) the value of <mute> does not change, i.e. the microphone mode is retained until
explicitly changed.
Syntax
Parameter Description
0
(P)
Mute off
1 Mute on
Test Command
AT+CMUT=?
Response(s)
+CMUT: (list of supported<mute>s)
OK
Read Command
AT+CMUT?
Response(s)
+CMUT: <mute>
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CMUT=<mute>
Response(s)
OK
ERROR
+CME ERROR: <err>
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge  Last
GSM 07.07 ! % % % % % ! ! !
<mute>
(num)