EasyManua.ls Logo

Siemens Brodersen MC55 AT - AT^SSMSS Set Short Message Storage Sequence

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 367 of 475 3/17/06
Confidential / Released
13.24 AT^SSMSS Set Short Message Storage Sequence
The short message storage ''MT'' (see AT+CPMS) is a logical storage. It consists of two physical storages ''ME''
and ''SM''. This command allows to select the sequence of addressing this storage.
Syntax
Parameter Description
MT sequence
0
(&F)(P)
''MT'' storage is ''ME'' then ''SM
1 ''MT'' storage is ''SM'' then ''ME''
Note
Access to the SIM storage is faster. For compatibility with previous software re-leases, the ''MT'' sequence
<seq>=0 is the factory default.
Test Command
AT^SSMSS=?
Response(s)
^SSMSS: (list of supported) <seq>s
Read Command
AT^SSMSS?
Response(s)
^SSMSS: <seq>
OK
Write Command
AT^SSMSS=<seq>
Response(s)
OK
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
SIEMENS ! % % % % % ! ! !
<seq>
(num)

Table of Contents