EasyManuals Logo

Siemens Brodersen MC55 AT User Manual

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #308 background imageLoading...
Page #308 background image
MC55_ATC_V04.00 Page 308 of 475 3/17/06
Confidential / Released
12.6 AT+FCLASS Fax: Select, read or test service class
AT+FCLASS sets the ME to a particular mode of operation (data, fax). This allows the ME to process information
in a manner suitable for that type of information.
Syntax
Parameter Description
0
(&F)
Data (e.g. EIA/TIA-602 or ITU V.250)
1 Fax class 1 (EIA/TIA-578-A, Service Class 1)
2 Fax class 2 (EIA/TIA SP-2388, an early draft version of EIA/TIA-592-A - Ser-
vice class 2.1)
Notes
• Using Error Correcting Mode (ECM) when sending FAXes over GSM should be avoided.
• If <n> is set to 1 or 2, all incoming calls will be answered as fax calls when ATA is issued on multiplexer chan-
nel 1 resp. ASC0. For calls explicitly signaled as voice or data calls, this procedure will fail with result code
"NO CARRIER", but the incoming call will continue to ring.
It is possible to change the setting of <n> to 0 while the call is ringing, and accept the call afterwards with ATA.
Test Command
AT+FCLASS=?
Response(s)
(list of supported <n>s)
OK
Read Command
AT+FCLASS?
Response(s)
<n>
OK
Write Command
AT+FCLASS=<n>
Response(s)
OK
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge  Last
EIA/TIA-592-A ! % ! % ! ! ! ! !
<n>
(num)(&W)(&V)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Brodersen MC55 AT and is the answer not in the manual?

Siemens Brodersen MC55 AT Specifications

General IconGeneral
BrandSiemens
ModelBrodersen MC55 AT
CategoryModem
LanguageEnglish

Related product manuals