EasyManua.ls Logo

Siemens Brodersen MC55 AT - AT^SSDA Set SMS Display Availability

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 366 of 475 3/17/06
Confidential / Released
13.23 AT^SSDA Set SMS Display Availability
This command allows to notify the MC55 of its controlling application's capability to immediately display incoming
SMS on a display.
If the application is able to display incoming short messages, a class 0 message shall be displayed immediately.
However, if it does not, class 0 messages shall be treated as if no message class is determined (GSM 03.38[17]).
The effect of this command if <da>=1 is to determine the behavior of parameter <mt> of AT+CNMI:
If <da>=1 and <mt>=1 incoming class 0 mesages need to be acknowledged with AT+CNMA (see also AT+CNMI
and AT+CSMS)
If multiplex mode is enabled (AT+CMUX) and <da>=1 with <mt>=1 is set on any logical channel, all other chan-
nels have to use <mt>=0.
Syntax
Parameter Description
Display Availability
0
(&F)
Application is not able to display incoming short message
1 Application is able to display incoming short message
Note
If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0/ASC1) avoid different settings for
routing and indicating short messages. For example, if messages shall be routed directly to one instance of
the TE (set with AT+CNMI, AT^SSDA), it is not possible to activate the presentation of URCs with AT+CMER
or AT+CNMI on another instance. Any attempt to activate settings that conflict with existing settings on
another interface, will result in CME ERROR, or accordingly CMS ERROR.
Test Command
AT^SSDA=?
Response(s)
^SSDA:list of supported <da>s
OK
Read Command
AT^SSDA?
Response(s)
^SSDA:<da>
OK
Write Command
AT^SSDA=<da>
Response(s)
OK
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
SIEMENS ! % % % % % ! ! !
<da>