EasyManua.ls Logo

Siemens Brodersen MC55 AT - AT^SPLR Read Entry from the Preferred Operators List

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 189 of 475 3/17/06
Confidential / Released
8.15 AT^SPLR Read entry from the preferred operators list
The AT^SPLR write command returns used entries from the SIM list of preferred operators with <indexa>
between <index1> and <index2>. If <index2> is not given, only entry at <index1> is returned. The test com-
mand returns the whole index range supported by the SIM.
See also GSM 07.07: AT+CPOL
Syntax
Parameter Description
Location number to start reading from
Location number where to stop reading
Index range supported by the SIM card (between <index1> and <index2>)
Operator in numeric form; GSM location area identification number
Test Command
AT^SPLR=?
Response(s)
^SPLR:(list of supported) <indexa>s
OK
ERROR
+CME ERROR: <err>
Write Command
AT^SPLR=<index1>[, <index2>]
Response(s)
^SPLR: <index1><oper>
^SPLR: <index2><oper>
OK
ERROR
+CME ERROR: <err>
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
SIEMENS % % % % % % ! ! !
<index1>
(num)
<index2>
(num)
<indexa>
(num)
<oper>
(str)

Table of Contents