EasyManua.ls Logo

Siemens Brodersen MC55 AT - ATX Set CONNECT Result Code Format and Call Monitoring

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 35 of 475 3/17/06
Confidential / Released
2.6 ATX Set CONNECT result code format and call monitoring
ATX determines whether or not the TA detects the presence of dial tone and busy signal and whether or not TA
transmits particular result codes.
Syntax
Parameter Description
[0] CONNECT result code only returned, dial tone and busy detection are both dis-
abled.
1 CONNECT <text> result code only returned, dial tone and busy detection are
both disabled.
2 CONNECT <text> result code returned, dial tone detection is enabled, busy
detection is disabled.
3 CONNECT <text> result code returned, dial tone detection is disabled, busy
detection is enabled.
4
(&F)
CONNECT <text> result code returned, dial tone and busy detection are both
enabled.
Exec Command
ATX[<value>]
Response(s)
OK
ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
V.250 ! % % % % % ! ! !
<value>
(num)(&W)(&V)

Table of Contents