MC55_ATC_V04.00 Page 38 of 475 3/17/06
Confidential / Released
Unsolicited Result Codes
URC 1
^SYSSTART
Indicates that the ME has been started and is ready to operate. If autobauding is active (AT+IPR=0) the URC
is not generated.
URC 2
^SYSSTART CHARGE ONLY MODE
Indicates that the ME has entered the CHARGE ONLY mode. This occurs if the charger is connected while
the ME is in POWER DOWN mode. If autobauding is active (AT+IPR=0) the URC is not generated. In
CHARGE ONLY mode the ME is neither registered to the GSM network nor are the serial interfaces fully
accessible. Only the AT commands listed in Section 20.4, Availability of AT Commands Depending
on Operating Mode of ME can be used. For further details on charging refer to the Hardware Interface
Description [2].
Parameter Description
0 NON-CYCLIC SLEEP mode:
In this mode, the AT interface is not accessible. Consequently, after setting
<fun>=0, do not send further characters. Otherwise these characters remain
in the input buffer and may delay the output of an unsolicited result code.
The first wake-up event stops power saving and takes the ME back to full func-
tionality level <fun>=1.
[1]
(&F)(P)
Full functionality.
If the ME is in one of the CYCLIC SLEEP modes you can issue AT+CFUN=1
to stop power saving and return to full functionality.
Keep in mind that, unlike the reset command described below, this action does
not restart the ME but only changes the level of functionality. See parameter
<rst> for details on the reset.
5 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled while CTS is active. If char-
acters are recognized on the serial interface, the ME stays active for 2 seconds
after the last character was sent or received.
6 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled while CTS is active. If char-
acters are recognized on the serial interface, the ME stays active for 10 min-
utes after the last character was sent or received.
To ensure that power saving takes effect immediately, the ME stays active for
only 2 seconds after <fun>=6 was entered.
7 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled while CTS is active. If char-
acters are recognized on the serial interface, the ME stays active for 2 seconds
after the last character was sent or received. ME exits SLEEP mode only, if
AT+CFUN=1 is entered.
8 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled while CTS is active. If char-
acters are recognized on the serial interface, the ME stays active for 10 min-
utes after the last character was sent or received. ME exits SLEEP mode only,
if AT+CFUN=1 is entered.
To ensure that power saving takes effect immediately, the ME stays active for
only 2 seconds after <fun>=8 was entered.
9 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled while CTS is active. If char-
acters are recognized on the serial interface, the ME stays active after the last
character was sent or received for at least the time, which can be configured
<fun>
(num)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Brodersen MC55 AT and is the answer not in the manual?

Siemens Brodersen MC55 AT Specifications

General IconGeneral
BrandSiemens
ModelBrodersen MC55 AT
CategoryModem
LanguageEnglish

Related product manuals