EasyManuals Logo

Siemens Brodersen MC55 AT User Manual

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #225 background imageLoading...
Page #225 background image
MC55_ATC_V04.00 Page 225 of 475 3/17/06
Confidential / Released
10.1.2 Example: GPRS connection profile
^SICS: 1, "conType", "CSD"
The new CSD profile just created is indicated with all
related parameters set to their default.
^SICS: 1, "alphabet", "0"
Character set determined with AT+CSCS applies
when string parameters are input with AT^SICS.
^SICS: 1, "user", ""
No user name set.
^SICS: 1, "passwd", "*****"
Password masked with asteriks.
^SICS: 1, "inactTO", "20"
Inactivity timeout = 20s.
^SICS: 1, "calledNum", ""
No destination set.
^SICS: 1, "dataType", "1"
Remote device is analog, e.g. an analog modem.
^SICS: 2, "conType", ""
Profile with <conProfileId> 2 is still empty.
^SICS: 3, "conType", ""
Profile with <conProfileId> 3 is still empty.
^SICS: 4, "conType", ""
Profile with <conProfileId> 4 is still empty.
^SICS: 5, "conType", ""
Profile with <conProfileId> 5 is still empty.
OK
at^sics=0,conType,GPRS0
Select connection type GPRS0.
OK
AT^SICS=0,"inactTO", "20"
Inactivity timeout = 20s.
OK
AT^SICS=0,dns1,"193.254.160.1"
IP address of Primary DNS server.
OK
AT^SICS=0,passwd,t-d1
Password for GPRS services provided by the Ger-
man operator T-D1.
OK
AT^SICS=0,apn,"internet.t-d1.de"
APN to access the GPRS services provided by the
German operator T-D1.
OK

Table of Contents