MC55_ATC_V04.00 Page 322 of 475 3/17/06
Confidential / Released
12.20 AT+FPHCTO DTE Phase C Response Timeout
The timeout value <tout> determines how long the DCE will wait for a command after reaching the end of data
when transmitting in Phase C. When timeout is reached, the DCE assumes that there are no more pages or doc-
uments to send.
Syntax
Parameter Description
Timeout
Value in 100ms units
0...30
(P)
...255
Note
Used for Fax Class 2 only.
Read Command
AT+FPHCTO?
Response(s)
<tout>
OK
Write Command
AT+FPHCTO=<tout>
Response(s)
OK
If error is related to ME functionality
ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
EIA PN-2388 ! % ! % ! ! ! ! !
<tout>
(num)