10.2 AT^SICI Internet Connection Information
The AT^SICI read command requests the current status of the Internet connection profiles currently defined
with AT^SICS.
The AT^SICI write command displays the status of the specified Internet connection profile. If the connection
profile is not defined yet, the command returns a "+CME ERROR" response.
Syntax
Parameter Description
Internet connection profile identifier as defined by AT^SICS (<conProfileId>).
0...5
State of the Internet connection profile.
0 Down - Internet connection is defined but not connected.
1 Connecting - A service has been opened and so the Internet connection is ini-
tated.
2 Up - Internet connection is established and usable by one or more services.
3 Limited Up - Internet connection is established, but temporarily no network cov-
erage.
4 Closing - Internet connection is terminating.
Test Command
AT^SICI=?
Response(s)
[^SICI:(list of defined <conProfileId>s)]
OK
Read Command
AT^SICI?
Response(s)
[^SICI: <conProfileId>, <conState>, <numServices>, <conAddr>]
[^SICI: ...]
OK
Write Command
AT^SICI=<conProfileId>
Response(s)
^SICI: <conProfileId>, <conState>, <numServices>, <conAddr>
OK
ERROR
+CME ERROR: <err>
PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
! % % % % % ! ! !
<conProfileId>
(num)
<conState>
(num)