EasyManua.ls Logo

Siemens Brodersen MC55 AT - AT+CNMA New Message Acknowledgement to ME;TE, Only Phase 2

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 347 of 475 3/17/06
Confidential / Released
13.10 AT+CNMA New Message Acknowledgement to ME/TE, only
phase 2+
The write / execute command confirms successful receipt of a new message (SMS-DELIVER or SMS-STATUS-
REPORT) routed directly to the TE. TA shall not send another +CMT or +CDS result code to TE until previous
one is acknowledged. If ME does not receive acknowledgement within required time (network time-out), ME
sends RP-ERROR to the network. TA shall automatically disable routing to TE by setting both <mt> and <ds>
values of AT+CNMI to zero.
Syntax
Parameter Description
Parameter required only for PDU mode.
0 Command operates similarly as in text mode.
Notes
The execute / write command shall only be used when AT+CSMS parameter <service> equals 1 (= phase
2+).
The execute command can be used no matter whether text mode or PDU mode is activated. The write com-
mand is designed for the PDU mode only.
If multiplex mode is activated (AT+CMUX=0) the AT+CNMI parameter will be set to zero on all channels, if one
channel fails to acknowledge an incoming message within the required time.
Test Command
AT+CNMA=?
Response(s)
+CNMA: (list of supported <n>s)
OK
Exec Command
AT+CNMA
Response(s)
OK
ERROR
+CMS ERROR
Write Command
AT+CNMA=<n>
Response(s)
OK
ERROR
+CMS ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
GSM 07.05 % % % % % % ! ! !
<n>
(num)

Table of Contents