17.17 AT^SNFV Set loudspeaker volume
AT^SNFV can be used to set the volume of the loudspeaker to the value <outCalibrate> addressed by <out-
Step>. The read and write commands refer to the active audio mode. The write command works only in audio
modes 2 to 6.
Syntax
Parameter Description
The actual volume of each step is defined by the parameter <outCalibrate>, which can be set with AT^SNFO.
0...4
(P)
Notes
• Any change to <outStep> takes effect in audio modes 2 to 6. That is, when you change <outStep> and
then select another mode with AT^SNFS, the same step will be applied. Nevertheless, the actual volume can
be quite different, depending on the values of <outCalibrate> set in each mode. The only exception is
audio mode 1 which is fixed to <outStep>=4.
• <outStep> is stored non-volatile when the ME is powered down with AT^SMSO or reset with AT+CFUN=1,1.
<outStep> is not stored by AT^SNFW.
• <outStep> can also be changed by AT^SNFO (Section 17.13) and AT+CLVL (Section 17.4).
Test Command
AT^SNFV=?
Response(s)
^SNFV: (list of supported <outStep>s)
OK
Read Command
AT^SNFV?
Response(s)
^SNFV: <outStep>
OK
Write Command
AT^SNFV=<outStep>
Response(s)
OK
ERROR
+CME ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge  Last
SIEMENS ! % % % % % ! ! !
<outStep>
(num)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Brodersen MC55 AT and is the answer not in the manual?

Siemens Brodersen MC55 AT Specifications

General IconGeneral
BrandSiemens
ModelBrodersen MC55 AT
CategoryModem
LanguageEnglish

Related product manuals