13.15 AT+CSDH Show SMS text mode parameters
The write command sets whether or not detailed header information is shown in text mode result codes.
Syntax
Parameter Description
[0]
(&F)
Do not show header values defined in commands AT+CSCA and AT+CSMP
(<sca>, <tosca>,<fo>,<vp>, <pid> and <dcs>) nor <length>, <toda> or
<tooa> in "+CMTI", AT+CMGL, AT+CMGR result codes for SMS-DELIVERs and
SMS-SUBMITs in text mode; for SMS-COMMANDs in +CMGR result code, do
not show <pid>,<mn>,<da>, <toda>, <length> or <cdata>
1 Show the values in result codes
Test Command
AT+CSDH=?
Response(s)
+CSDH: ((list of supported <show>s)
OK
Read Command
AT+CSDH?
Response(s)
+CSDH:<show>
OK
Write Command
AT+CSDH=<show>
Response(s)
+CSDH: <show>
OK
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
GSM 07.05 % % % % % % ! ! !
<show>
(num)(&W)

Table of Contents