13.16 AT+CSMP Set SMS text Mode Parameters
The write command selects values for additional parameters needed when the short message is sent to the net-
work or placed in a storage when text format message mode is selected.
It is possible to set the validity period starting from the time when the short message is received by the SMSC
(<vp> is in range 0... 255) or define the absolute time of the validity period termination (<vp> is a string). The
format of <vp> is given by <fo>. If TA supports the enhanced validity period format, see GSM 03.40), it shall be
given as a hexadecimal coded string (e.g. <pdu>) with quotes.
Syntax
Parameter Description
First Octet
depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17),
SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format
0...17
(&F)
...255
Depending on SMS-SUBMIT <fo> setting: GSM 03.40 TP-Validity-Period either in integer format or in time-
string format (refer <dt>)
0...167
(&F)
...255
Data Coding Scheme
GSM 03.38 SMS Data Coding Scheme, or Cell Broadcast Data Coding Scheme in integer format
0
(&F)
...247
Test Command
AT+CSMP=?
Response(s)
OK
Read Command
AT+CSMP?
Response(s)
+CSMP:<fo>, <vp>/ <scts>, <pid>, <dcs>
OK
Write Command
AT+CSMP=<fo>[, <vp>/<scts>[, <pid>[, <dcs>]]]
Response(s)
+CSMP: <index>
OK
If sending fails
ERROR
+CMS ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
GSM 07.05 % % % % % % ! ! !
<fo>
(num)
<vp>
(num)
<dcs>
(num)