Host 1 rejects the Socket connection request:
^SISO: 6, ""
^SISO: 7, ""
^SISO: 8, ""
^SISO: 9, ""
OK
at^sisc=0
Host 1 rejects the connection request, where 0 is the
ID of the dynamically assigned service profile.
OK
at^siso?
Query the current status of services.
^SISO: 0, ""
The dynamically assigned service profile is free
again. The Socket listener stays at <srvState>=3
(listening) and <socketState>=3 (LISTENER).
^SISO: 1, ""
^SISO: 2, ""
^SISO: 3, ""
^SISO: 4, "Socket","3","3","0","0","10.10.0.187:65534","0.0.0.0:0"
^SISO: 6, ""
^SISO: 7, ""
^SISO: 8, ""
^SISO: 9, ""
OK