EasyManuals Logo

Siemens Brodersen MC55 AT User Manual

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
MC55_ATC_V04.00 Page 63 of 475 3/17/06
Confidential / Released
String values and their <indValue> ranges.
More indications are available via AT^SIND. Therefore use of AT^SIND for control of all indications is recom-
mended.
The following indications are accessible via AT+CIND:
"battchg" Battery charge level 0..4 or 5 if no measuring is performed, e.g because no bat-
tery is connected. Also refer to AT^SBC.
"signal" Signal quality (0..7) or (99) if not measurable
The indicated value is the bit error rate of the signal received. Bit errors are esti-
mated values. See also AT+CSQ.
"service" Service availability (0-1)
0: Not registered to any network
1: Registered to home network or, if "roam"=1 then registered to another net-
work
"sounder" Sounder activity (0-1)
Reports every event that causes the ME to generate a tone.
Value 1 means for example:
Incoming call - ME is ringing. Note that the URC "+CIEV: sounder" will be out-
put only if ringing tones are activated with AT^SRTC.
Waiting call - ME generates waiting call tone (if call waiting is enabled).
Outgoing call - ME generates Call Progress tone.
Outgoing call - ME generates BUSY tone.
The value changes to 0 when the tone stops.
"message" Unread short message at memory location <mem1> (0-1); refer to AT+CPMS
"call" Call in progress (0-1). Indicator value is "1" if at least one call is in state "active"
or "held".
Depending on the parameter <succ> selected with AT^SCFG the indicator
"call" will be issued
• when a state transition ends in state "active" or state "unknown", if
<succ>="restricted",
• when any state transition (including transitions beginning or ending in state
"unknown") occurs in the list of active calls or when a traffic channel is
established, if <succ>="verbose".
Also refer to Section 7.1, Call Status Information.
"roam" Roaming indicator (0-1)
0: Registered to home network or not registered
1: Registered to other network
"smsfull" A short message memory storage in the MT has become full (1) or memory
locations are available (0), i.e. range is (0-1)
"rssi" Received signal (field) strength (0..5) or (99) if not measurable
0: signal strength <= -112 dbm
1-4: signal strength in 15 dbm steps
5: signal strength >= -51 dbm
Received signal (field) strength can also be obtained with AT+CSQ. However,
the signal strength is scaled to value range 0..31 by this command.
0 Indicator is deregistered. The indicator will not be presented as "+CIEV" URC,
but can be queried with AT+CIND?.
[1]
(&F)(P)
Indicator is registered, indicator event report allowed.
<indDescr>
(str)
<mode>
(num)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Brodersen MC55 AT and is the answer not in the manual?

Siemens Brodersen MC55 AT Specifications

General IconGeneral
BrandSiemens
ModelBrodersen MC55 AT
CategoryModem
LanguageEnglish

Related product manuals