Setup of the Person Machine Interfac
e
Person Machine Interface with FBP [AU]
3
24 | 184
Building Technologies
A6V10211076_i_en_
--
Fire Safety
2015
12
15
1 Alarm indicator Light up red in the event of an alarm
2 Display Event indication, e.g. type, place, status of event
Menu, element and command indication
Instructions may be displayed in the event of an alarm
3 Navigation buttons
For navigation in the display for, e.g., menu and command selection
and scrolling in lists
Access level 2,2 required
4
Keypad with Menu key, ok key
and Cancel key
Keypad for PIN entry (password), shortcut (menus), address entry
(element ID), parameter entry, entry of customer text
The menu button opens the main menu
The <ok> button can be used to run a selected command or open a
menu item. In windows with an entry field, the <ok> button moves the
cursor to the next entry.
With the <C> cancel button, any operation sequence can be
canceled, and any open list or window can be closed.
PIN entry required
5 Operating unit (AU) Pre-configured LEDs
LEDs which can be configured according to specific customer
requirements
6 Key switch Enabling fire brigade operation with access level 2,1
7
<Silence buzzer>, <Silence
Alarm>, <Reset>, and
<Disable> standard buttons
Access level 2,1 required; fire brigade operation with key switch:
<Silence buzzer> switches the buzzer off
<Silence Alarm> deactivates alarm devices
<Reset> resets all events that can be reset
<Disable> stops the alarm in all 'Zones' which have issued an alarm
13
123
456
789
*
0#
C
ok
a
b
c
~
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
d
e
f
001 AAA
001 ABC
ABC
YYYY
ZZZ ZZZ ZZZ
FIRE BRIGADE PANEL
FIRE
SMOKE CONTROL
ACTIVATED
WARNING SYSTEM
ACTIVATED
SYSTEM
POWER
FAULT
SEVERAL ALARMS
SILENCE BUZZER
SILENCE ALARM
RESET
DISABLE
FIRE PROTECTION
ACTIVATED
CONTROL FUNCTION
ACTIVATED/CONFIRM.
WARNING SYSTEM
SILENCED
FAULT
ISOLATION
DET EC TOR T ES T
CONTROL FUNCTION
ACTIVATED
FAULT/OFF
WARNING SYSTEM
ACTIVATED
FAULT/OFF
FIR E PR OTE CTI ON
ACTIVATED
FAULT/OFF
SMOKE CONTROL
ACTIVATED
FAULT/OFF
ACKNOWLEDGE
PREMISES MANNED
ALARM ROUTING
ACTIVATED
FC72x-xx
ALARM ROUTING
ACTIVATED
FAULT/OFF
11
6
12
7
910
14
15
1
2
3
4
5
8

Table of Contents

Other manuals for Siemens FT724

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens FT724 and is the answer not in the manual?

Siemens FT724 Specifications

General IconGeneral
BrandSiemens
ModelFT724
CategoryControl Panel
LanguageEnglish

Related product manuals