Comments about the System’s Programming Codes
Configuring the System Specifically for the Client For internal distribution only
A31003-K1250-S100-12-7619
7-26 HiPath 1100, Service Manual
Polarity Inversion (58)
If your Carrier provides this feature, call detail recording occurs in real time. That is,
when the called party answers the phone, the public exchange sends a signal for the
system to start call detail recording.
Dial Tone Detection (60)
This setting has the system wait for a dial tone detection on the public exchange be-
fore making it available to the user. With Standard MF telephones the number dialed
will be transmitted to the external line approximately 4 to 5 seconds after the last digit
is dialed.
Connection Type (33)
This setting determines whether the external analog line that is connected to one of
the HiPath 1100 systems is also interconnected to another C.O. or PABX.
Second External Access Code (34)
This setting determines the code to be sent by the Satellite PABX in accordance with
the access code for external lines on the Master PABX. This code is used for deter-
mining the availability of a dial tone on an external line.
Auto-Seizure Mode for an External Line (036)
This feature dials an external call when the handset is lifted, without using an access
code (e.g., 0). When this setting is selected you must enter a code to dial internal
calls or activate the Extension key.
False tone (063)
This sends an external line dial tone even when there is no external line available.
External line present (079)
This setting allows you to determine whether a given external line exists.
Waiting time for a Second Attendant to answer a call on an external analog line
(083)
This setting specifies a timeout before the call starts ringing at the extension.
Activating this feature may impact the programming of the Dialing Mode (Code 68),
assuming option 0 (Automatic ID) is selected. It is recommended that you reconfig-
ure the Dialing Mode (Pulse or Tone) for the extensions.
If LCR (configured via the HiPath 1100 Manager) or Emergency Numbers is en-