Option Modules (MO)
Modules For internal distribution only
A31003-K1250-S100-12-7619
3-30 HiPath 1100, Service Manual
Primary Access
Connector for TME1 Module Configuration
The connector’s function is to connect a PC or modem to a module using a TME1
serial cable (see “TME1 Serial Cable” on page 3-55). This allows you to program the
module using the HiPath 1100 E1 Trunk Manager tool.
Figure 3-17 TME1 CAS access connection
Figure 3-18 Signal distribution on the TME1 module connector
Warning
Do not touch the TME1 module’s administrative serial interface connector (X803)
without first disconnecting all analog extensions and trunk connectors. Failure to fol-
low this procedure may expose the user to dangerous voltages.
The administrative serial interface connector (X803) as well as all other connectors
and interconnect cables should only be serviced by trained technical personnel.
2x coax cable
HiPath 1100
TME1
Modem
Public Network
2 = RX
1 = DCD
3 = TX
4 = DTR
5 = GND
9-pin Mini-DIN
connector
1
2
3
7
6
9
7 = RTS
6 = DSR
8 = CTS
9 = RI
!