Option Modules (MO
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
3-31
For internal distribution only Modules
DIP Switch Positions for the TME1 Module
By changing the positions of the DIP switches to ON (120 Ohms) or OFF (75 Ohms)
the following settings can be configured:
● DIP Switch 1 (S201)
It allows you to clean the Flash memory, select the baud rate and execute an auto-
test.
Figure 3-19 DIP Switch for the TME1 Module
Table 3-21 TME1 module, DIP switch 1
Switch Pro-
ce-
dure
Meaning Possible Settings
1 FE Delete Flash memory
ON - Deletes Flash memory when the PABX is turned
on
OFF - System will work as usual (default).
2 EST Extended autotest
ON - Activates autotest
OFF - Skips autotest (default).
3BR1
Baud rate configura-
tion
(3) OFF, (4) OFF and (5) OFF: 9600 bps
(3) OFF, (4) OFF and (5) ON: 19200 bps
(3) OFF, (4) ON and (5) OFF: 38400 bps
(3) OFF, (4) ON and (5) ON: 57600 bps (default)
4BR2
5BR3
6RES
For future applications7RES
8RES