Option Modules (MO)
Modules For internal distribution only
A31003-K1250-S100-12-7619
3-32 HiPath 1100, Service Manual
DIP Switch 2 (S401)
7-segment Display Readings (H801)
If an error occurs during software installation, clear the Flash memory and reinstall
the software. Follow these instructions:
Turn the PABX off
Set Switch 1 (FE) to ON
Turn the PABX on again
Wait for F and E to show on the display
Turn the PABX off
Set switch 1 (FE) to OFF again
Turn on the PABX
It is recommended that you do not change the DIP Switch 2 default setting.
Table 3-22 TME1 module, DIP switch 2
Switch Procedure Default
1 DSP - BIO OFF
2Reserved OFF
3Reserved OFF
4 Battery connection OFF
5MODCK2 ON
6WDI ON
7MODCK1 OFF
8 E1 Interface impedance OFF
Table 3-23 TME1 module display readings
Display Reading Meaning
8
Continuous Module is powered.
]
Continuous Starting TME1 module.