Option Modules (MO
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
3-33
For internal distribution only Modules
E
Continuous
Waits 10 seconds for a command from the software (Hi-
Path 1100 E1 Trunk Manager). If it receives no command af-
ter the specified time, the system resumes its usual oper-
ation.
8
Continuous Transferring memory contents to DRAM memory.
Continuous Checking and validating contents of Flash memory.
P
Continuous TME1 module is active but CAS link is out of service.
A
Continuous TME1 module is active with CAS link.
I
Continuous
“Unpacking” HiPath E1 Trunk Manager.
3
Continuous
7
Continuous Writing software to Flash memory.
F
Continuous Checking transferred data.
o
Continuous
E1 and CAS links are still out of service; the reason is un-
known.
Cycle - Live Clearing Flash memory.
f e
Alternating Flash memory cleared.
h
Continuous
No software in Flash memory. Waiting for Tool to download
software
A.
Continuous
Module is working as a Master and synchronizing TME1
modules.
Table 3-23 TME1 module display readings
Display Reading Meaning
3