1-13
Batch
flexible
, Manual
C79000-G7076-C650-02
1.5.3 BATCH
flexible
Object Manager (BOM)
The BATCH flexible Object Manager carries out the higher-level
management functions for the BATCH objects.
S List functions:
the following BATCH objects are shown in the form of a list:
Applications all BATCH flexible applications in single user or
multi-user systems
Recipes Apparatus recipes in the database
Batches: Batches in the database
Users: currently configured users and user groups
Processing: all objects currently being processed by BATCH flexible
applications
S Administrative functions:
Applications: starting or terminating BATCH applications
Recipes: inserting, opening, copying, deleting...
Batches: inserting, opening, deleting...
Production orders: opening, deleting, exporting...
Users: setting up users and user groups with the corresponding
authorizations
Editing: canceling the processing status of occupied objects in the
database
Configuration data: reading and adding to ES configuration data,
checking for completeness
S Logging:
Structure, examples of batch record, recipe record
Functions
System overview

Table of Contents

Other manuals for Siemens SIMATIC PCS7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC PCS7 and is the answer not in the manual?

Siemens SIMATIC PCS7 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC PCS7
CategoryControl Systems
LanguageEnglish

Related product manuals