1-14
Batch
flexible
, Manual
C79000-G7076-C650-02
1.5.4 Control recipe generator
The background application ‘Control recipe generator‘ does not have a user
interface. The control recipe generator starts automatically after a batch has
been released.
The state of the batch is shown during control recipe generation by Release
running being displayed. Following successful control recipe generation the
batch state is changed to Released.
A control recipe is the copy of a control recipe with adapted quantities and
specification of the parameters which are still open ($ variables). This
satisfies the requirement for on-line processing of the batch by batch control.
Should an error occur during control recipe generation, the batch status
Release error is displayed for this batch.