8.16.4.2 Password ......................................................................................................................... 258
8.16.4.3 Con󹪝guring a safety function ........................................................................................... 260
8.16.4.4 Interconnecting the "STO active" signal............................................................................. 261
8.16.4.5 Signal 󹪝lter for STO selection............................................................................................ 262
8.16.4.6 Setting the signal 󹪝lter for STO selection........................................................................... 264
8.16.4.7 Forced checking procedure .............................................................................................. 264
8.16.4.8 Setting forced checking procedure ................................................................................... 265
8.16.4.9 Complete commissioning................................................................................................. 267
8.16.4.10 Checking the assignment of the digital inputs .................................................................. 268
8.16.4.11 Acceptance test ............................................................................................................... 269
8.17 Setpoints ......................................................................................................................... 270
8.17.1 Overview......................................................................................................................... 270
8.17.2 Analog input as setpoint source ....................................................................................... 272
8.17.3 Specifying the setpoint via the 󹪝eldbus............................................................................. 273
8.17.4 Motorized potentiometer as setpoint source ..................................................................... 274
8.17.5 Fixed speed setpoint as setpoint source............................................................................ 276
8.18 Setpoint processing.......................................................................................................... 279
8.18.1 Overview......................................................................................................................... 279
8.18.2 Invert setpoint ................................................................................................................. 281
8.18.3 Inhibit direction of rotation .............................................................................................. 282
8.18.4 Skip frequency bands and minimum speed....................................................................... 283
8.18.5 Speed limitation .............................................................................................................. 285
8.18.6 Ramp-function generator................................................................................................. 286
8.19 PID technology controller................................................................................................. 289
8.19.1 Autotuning the PID technology controller......................................................................... 296
8.20 Motor control................................................................................................................... 299
8.20.1 Reactor, 󹪝lter and cable resistance at the converter output................................................ 299
8.20.2 U/f control ....................................................................................................................... 300
8.20.2.1 U/f control ....................................................................................................................... 300
8.20.2.2 Optimizing motor starting................................................................................................ 304
8.20.2.3 U/f control with Standard Drive Control ............................................................................ 305
8.20.2.4 Optimizing motor starting using Standard Drive Control ................................................... 308
8.20.3 Sensorless vector control.................................................................................................. 310
8.20.3.1 Structure of vector control without encoder (sensorless)................................................... 310
8.20.3.2 Optimizing the speed controller ....................................................................................... 312
8.20.3.3 Advanced settings............................................................................................................ 314
8.20.3.4 Friction characteristic....................................................................................................... 316
8.20.3.5 Moment of inertia estimator ............................................................................................ 319
8.20.4 Application examples for closed-loop motor control.......................................................... 324
8.21 Electrically braking the motor........................................................................................... 324
8.21.1 Electrical braking ............................................................................................................. 324
8.21.2 DC braking....................................................................................................................... 326
8.21.3 Compound braking .......................................................................................................... 331
8.21.4 Dynamic braking.............................................................................................................. 332
8.22 Overcurrent protection..................................................................................................... 336
8.23 Converter protection using temperature monitoring ......................................................... 337
8.24 Motor protection with temperature sensor ....................................................................... 340
8.25 Motor protection by calculating the temperature .............................................................. 342
Table of contents
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 9

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage

Related product manuals