EasyManuals Logo

Siemens SINAMICS G120C DP User Manual

Siemens SINAMICS G120C DP
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
8.26 How do I achieve a motor overload protection in accordance with IEC/UL 61800-5-1?........ 343
8.27 Motor and converter protection by limiting the voltage..................................................... 344
8.28 Flying restart – switching on while the motor is running................................................... 346
8.29 Automatic restart............................................................................................................. 348
8.30 Kinetic bu󹪜ering (Vdc min control)................................................................................... 350
8.31 E󹪟ciency optimization..................................................................................................... 352
8.32 Line contactor control...................................................................................................... 355
8.33 Calculating the energy saving for 󹪞uid 󹪞ow machines....................................................... 357
8.34 Switchover between di󹪜erent settings.............................................................................. 359
9 Alarms, faults and system messages................................................................................................. 361
9.1 Operating states indicated via LEDs .................................................................................. 361
9.2 Identi󹪝cation & maintenance data (I&M) .......................................................................... 365
9.3 Alarms, alarm bu󹪜er, and alarm history ............................................................................ 366
9.4 Faults, alarm bu󹪜er and alarm history............................................................................... 369
9.5 List of alarms and faults ................................................................................................... 372
10 Corrective maintenance .................................................................................................................... 379
10.1 Replacing the converter hardware .................................................................................... 380
10.2 Downloading the converter settings................................................................................. 382
10.2.1 Converter without enabled safety functions ..................................................................... 382
10.2.1.1 Automatic download from the memory card .................................................................... 382
10.2.1.2 Manual downloading from the memory card with the BOP-2 ............................................ 383
10.2.1.3 Manual download from the memory card using Startdrive................................................ 384
10.2.1.4 Download from BOP-2 operator panel .............................................................................. 385
10.2.1.5 Download from IOP-2 operator panel ............................................................................... 386
10.2.1.6 Download from Smart Access........................................................................................... 387
10.2.1.7 Download from the PC using Startdrive ............................................................................ 389
10.2.2 Converter with enabled safety functions........................................................................... 390
10.2.2.1 Automatic download from the memory card .................................................................... 390
10.2.2.2 Manual downloading from the memory card with the BOP-2 ............................................ 391
10.2.2.3 Download from BOP-2 operator panel .............................................................................. 393
10.2.2.4 Download from IOP-2 operator panel ............................................................................... 394
10.2.2.5 Download from Smart Access........................................................................................... 396
10.2.2.6 Download from the PC using Startdrive ............................................................................ 399
10.2.3 Download with active know-how protection with copy protection..................................... 401
10.3 PROFINET device name .................................................................................................... 403
10.4 Spare parts ...................................................................................................................... 403
10.4.1 Overview......................................................................................................................... 403
10.4.2 Replace the fan unit for the heat sink ............................................................................... 405
10.4.3 Replacing the fan for FSD ... FSF - G120C.......................................................................... 406
10.4.4 Replacing the roof-mounted fan....................................................................................... 408
10.5 Firmware upgrade and downgrade................................................................................... 410
10.5.1 Overview......................................................................................................................... 410
Table of contents
SINAMICS G120C Converters
10 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage

Related product manuals