Commissioning know-how protection
1. Check as to whether you must extend the exception list.
List of exceptions (Page180)
2. Activate the know-how protection.
Know-how protection (Page181)
Parameter
Table 7-2 Parameters that can be changed with active know-how protection
Number Name
p0003 Access level / Acc_level
p0010 Drive commissioning parameter lter / Drv comm par_lt
p0124[0...n] CU detection using LED / CU detect LED
p0791[0...1] CO: Fieldbus analog outputs / Fieldbus AO
p0970 Reset drive parameters / Drive par reset
p0971 Save parameters / Sav par
p0972 Drive unit reset / Drv_unit reset
p2040 Fieldbus interface monitoring time / Fieldbus t_monit
p2111 Alarm counter / Alarm counter
p3950 Service parameter / Serv par
p3981 Acknowledge drive object faults / Ackn DO faults
p3985 Master control mode selection / PcCtrl mode select
p7761 Write protection / Write protection
p8402[0...8] RTC daylight saving time setting / RTC DST
p8805 Identication and Maintenance 4 Conguration / I&M 4 Cong
p8806[0...53] Identication and Maintenance 1 / I&M 1
p8807[0...15] Identication and Maintenance 2 / I&M 2
p8808[0...53] Identication and Maintenance 3 / I&M 3
p8809[0...53] Identication and Maintenance 4 / I&M 4
p8980 EtherNet/IP prole / Eth/IP prole
p8981 EtherNet/IP ODVA STOP mode / Eth/IP ODVA STOP
p8982 EtherNet/IP ODVA speed scaling / Eth/IP ODVA n scal
p8983 EtherNet/IP ODVA torque scaling / Eth/IP ODVA M scal
p9400 Safely remove memory card / Mem_card rem
p9484 BICO interconnections search signal source / BICO S_src srch
Table 7-3 Parameters that can be read with active know-how protection
Number Name
p0015 Macro drive unit / Macro drv unit
p0100 IEC/NEMA Standards / IEC/NEMA Standards
p0170 Number of Command Data Sets (CDS) / CDS count
Protecting the converter settings
7.2Know-how protection
SINAMICS G120C Converters