Figure8-57 Overview of the function of the moment of inertia estimator
When using the moment of inertia estimator, we recommend that you also activate the
friction characteristic.
Friction characteristic (Page316)
How does the converter calculate the load torque?
0
/
,QHUWLDHVWLPDWRULV
DFWLYH
0RWRUWRUTXH0
0
6SHHG
/RDGHVWLPDWRULV
DFWLYH
W
W
W
W
Figure8-58 Calculating the load torque
At low speeds, the converter calculates the load torque M
L
from the actual motor torque.
The calculation takes place under the following conditions:
Speed ≥ p1226
Acceleration setpoint < 8 1/s
2
(≙ speed change 480rpm per s)
Acceleration × moment of inertia (r1493) < 0.9 × p1560
Advanced commissioning
8.20Motor control
SINAMICS G120C Converters
320 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage

Related product manuals