6.20.14 Dosing signals
Dosing signals during extra coarse phase [feedOptionsXCoarse]
Defines which signals are switched in the "Extra coarse" dosing phase in three-stage dosing
(with extra coarse, coarse and fine phase).
Selection code Meaning
0 (default) Extra coarse phase is omitted
1 Only "Extra coarse signal"
3 "Extra coarse signal" + "Coarse signal"
7 "Extra coarse signal" + "Coarse signal" + "Fine signal"
Dosing signals during coarse phase [feedOptionsCoarse]
Defines which signals are switched in the "coarse" dosing phase.
Selection code Meaning
1 (default) Only with coarse signal
3 With coarse and fine signal
6.20.15 Delete tare in weighing step 0 [deleteTareStep0]
Selection code Meaning
0 (default) Do not delete tare
1 Delete tare memory automatically on transition to weighing step 0
6.21 DR28 Configuration of additional string for protocols
6.21.1 Log with additional string [addAdditionalText]
The freely definable additional string [additionalText] with 42 characters is transmitted from the
CPU to the electronic weighing system. When you save the additional string in the protocol,
extra information such as batch numbers or similar is saved in the scale protocols.
Selection code
[addAdditionalText]
Meaning
0 (default) Do not save additional string in protocol
1 Save additional string in protocol
Parameter assignment/addressing
6.21 DR28 Configuration of additional string for protocols
Technology module TM SIWAREX WP351 HF
102 Operating Instructions, 01/2020, A5E47521010-AA