6.9.5 Monitoring of digital outputs [monitoringOfDQ]
Selection code Function
0 Monitoring inactive
1 Monitoring active
6.9.6 Reaction of digital outputs to a CPU stop / failure
[behaviourOfDQOnCPUStopOrFailure]
Selection code Function
0 Set substitute values
1 Retain function
6.9.7 Behavior of digital outputs on error [behaviourOfDQOnError]
Selection code Function
0 (default) Set substitute values
1 Retain function
6.9.8 Substitute value for DQ.0 to DQ.3 on error
An output is set in the event of a fault.
Selection code 0 is preset and resets the outputs in the event of a fault (operating error) or on
a SIMATIC STOP.
Procedure
NOTICE
Risk to the plant
If an output is set following a fault (operating error), this can pose a risk for the plant.
Ensure that the parameters are correctly set.