See also
Commands (Page 111)
6.5.2 Scale name [scaleName]
You can select any name, but it may not exceed 12 characters. You can enter any designation.
Note
The scale name cannot be changed after official verification.
6.5.3 Weight unit [weightUnit]
Sets the weight units.
Selection code Weight unit
0 mg Milligram
1 g Gram
2 (default) kg Kilogram
3 t Metric ton
4 oz Ounce
5 lb Pound
6 T Short ton
7 TL Long ton
8 N Newton
9 No unit
The weight unit selection has no effect on the internal weight calculation. It involves only ASCII
characters. Thus, all parameters with weight must be specified with appropriate conversion
when there is a change of weight unit.
6.5.4 Gross indicator [grossIndicator]
The gross identifier specifies the letter, B (for brutto) or G (for gross), to be used in the display
for gross weights.
Parameter assignment/addressing
6.5 DR03 Calibration parameters
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 59