6.15 DR20 Configuration of set point [setPoint]
Introduction
The set point in "CW - Automatic check weigher" defines the reference weight of an individual
dosing to be checked with the defined weight unit (Page 59).
Procedure
1. Enter the set point [setPoint] in DR20.
The set point is smaller than the maximum permissible set point (Page 98) from DR25.
2. Write DR20.
6.16 DR21 Configuration of total set point [totalSetPoint]
6.16.1 DR21 Configuration of total set point in DTI
Introduction
The total set point in "DTI - Discontinuous totalizing automatic weighing instruments" specifies
the total weight to be loaded with the defined weight unit (Page 59).
Material in feed intake (pre-signal) [materialDisposed]
Specifies the material weight in the feed intake to the scale with the defined weight unit.
Maximum allowed total set point undercut [maxTotalSetPointDeviation]
Defines the maximum permissible underrun of the total weight to be loaded with the defined
weight unit.
Requirement
You have selected the weighing operating mode DTI Discontinuous totalizing automatic
weighing instrument (Page 57).
Parameter assignment/addressing
6.16 DR21 Configuration of total set point [totalSetPoint]
Technology module TM SIWAREX WP351 HF
86 Operating Instructions, 01/2020, A5E47521010-AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens TM SIWAREX WP351 HF and is the answer not in the manual?

Siemens TM SIWAREX WP351 HF Specifications

General IconGeneral
BrandSiemens
ModelTM SIWAREX WP351 HF
CategoryControl Unit
LanguageEnglish

Related product manuals