6.23.15 Gross process weight 1 [grossProcessWeight1], Net process weight 1
[netProcessWeight1], Tare process weight [tareProcessWeight]
These are the gross, net and tare weights in high-resolution process form.
6.23.16 Gross weight [grossWeight], Net weight [netWeight], Tare weight [tareWeight]
These are the gross, net and tare weights after rounding and filtering defined in data record 3.
6.23.17 Gross/net weight x10 [netWeightX10]
This is the gross and net weight after rounding according to settings in DR03 and a resolution
raised by a factor of 10.
6.23.18 Gross process weight 2 [grossProcessWeight2], Net process weight 2
[netProcessWeight2]
These are the high-resolution, internal process values of the gross and net weight after filtering
according to filters 1 and 2 (DR03).
6.23.19 Last net process weight [lastNetProcessWeight], Last net weight [lastNetWeight]
The parameters show the last dosed net process weight or net weight.
6.23.20 Totalizer 1 [totalizer1] and Totalizer 2 [totalizer2]
Two totalizer memories that you reset separately using a command. Delete totalizer 1:
Command code: 651; Delete totalizer 2: Command code: 652. In NAWI and CWI modes, the
dosed weight is added to the totalizers after the tolerance check. In weighing operating mode
GFI, the actual weight determined by the tolerance check in checked cycles is cumulated. For
cycles without tolerance check, the set point set in DR20 is included in the calculated totalizers.
In DTI mode, totalizer 1 represents the legal-for-trade totalizer.
6.23.21 Youngest protocol ID [youngestLogId]
After a successful logging, the "Youngest protocol-ID" parameter is incremented and
represents the last protocol ID to be created.
Parameter assignment/addressing
6.23 DR30 Read out process state
Technology module TM SIWAREX WP351 HF
106 Operating Instructions, 01/2020, A5E47521010-AA