Table 6-1 Example parameter table
DR Parameter S7 name Type Min.
value
Max.
value
Modbus ad‐
dress
Write pro‐
tection
Access
4 Calibration dig‐
its 0
(calculated)
calibrationDigits0calculated DINT 0 - 1200 x r
6.2 TIA Portal user program
6.2.1 Commissioning the electronic weighing system with TIA Portal
Procedure
1. Download the "Ready to use" TIA Portal example project for the technology module TM
SIWAREX WP351 HF (
https://support.industry.siemens.com/cs/ww/en/ps/17781/dl) from
the Internet.
The example project must be compatible with your SIMATIC controller.
2. Navigate to the electronic weighing system in the hardware catalog task card: Technology
modules > Weighing > SIWAREX > TM SIWAREX WP351 HF.
3. Drag-and-drop the electronic weighing system in the ET 200SP rack.
4. Click on the "General" sub-tab in the "Properties" tab.
Parameter assignment/addressing
6.2 TIA Portal user program
Technology module TM SIWAREX WP351 HF
38 Operating Instructions, 01/2020, A5E47521010-AA