5. In the left-hand tree, navigate to TM SIWAREX WP351 HF.
Web server Activate the access for the Web server.
HTTPS Function is not supported with FW version 1.0.0.
Logon name / Access right /
Password
Create up to five different users.
Assign the "Read" or "Read and write" permission individually to
each user.
Read means that the user has read-only access to the Web server
and can create and download a backup of the current configuration.
The user cannot change data or start commands.
Invalid combination of logon name and password
The following combination is intended exclusively for emergency
access to the Web server.
Logon name: admin
Password: admin
For more on this, see section: AUTOHOTSPOT > Procedure in
case of loss of user data.
IP address IP address of the electronic weighing system
(default: 192.168.0.21)
Subnet mask Subnet mask of the electronic weighing system
(default: 255.255.255.0)
Set IP address in the project The IP address of the electronic weighing system is transmitted via
the hardware configuration during CPU startup.
The IP address is only specified via TIA Portal.
Permit adapting the IP ad‐
dress directly at the device
The IP address of the electronic weighing system is not assigned
via the TIA Portal.
● Assign the IP address via an external tool (e.g. PST Tool)
Use router Defines whether or not a router is used.
Router address IP address of the router
Device name Network name of the electronic weighing system
Parameter assignment/addressing
6.2 TIA Portal user program
Technology module TM SIWAREX WP351 HF