Technology messages Error code Description and remedy
2122 Inhibition time "extra coarse" error 2122 Inhibition time extra course. After expiration of the inhibition time
extra coarse, the extra coarse shut-off point was already exceeded
2123 Extra coarse shut-off point already
exceeded
2123 The extra coarse shut-off point is already exceeded before switch‐
ing on the extra coarse signal
2096 Restore point set 2096 A recovery point was successfully set.
2094 Backup/snapshot set 2094 Backup/snapshot was successfully set.
2095 Backup loaded 2095 Backup (or default values, if no backup) has been successfully loa‐
ded.
2097 Restore point loaded 2097 A recovery point was successfully loaded.
2098 Standard parameters loaded 2098 The standard parameters were successfully loaded.
2099 Factory settings loaded 2099 The factory settings were successfully loaded.
9.4.3 Data and command errors
Table 9-2 Data and command errors
Data and command errors Error code
[errorCode]
Add info
[errorAd‐
dInfo]
Description
5000 Data/command errors 5000 - Group error, at least one data/operating error present
6050 Unknown command 6050 - Issued command code is unknown. Check the command code.
6051 Command not possi‐
ble now
6051 - The desired command could not be executed because, for exam‐
ple, another process is already active at this time. Additional infor‐
mation contains details.
9500 Fault present
9501 No stability
9502 Waiting for stability
9507 Dosing active
9514 CPU is missing or not ready
9541 Emptying active
9680 SecureDisplay is missing or not visible
9681 Display command does not match the current display content of
SecureDisplay
6052 Service command er‐
ror
6052 Commands from the Service commands group could not be exe‐
cuted. Additional information contains details.
9510 Service mode not active
9511 Write protection enabled
9507 Dosing active
9512 Missing enable
9522 Calibration not yet complete
6053 Calibration command
error
6053 Command from the Calibration commands group could not be exe‐
cuted. Additional information contains details.
9510 Service mode not active
Interrupts/diagnostic messages
9.4 Operating errors
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 133

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens TM SIWAREX WP351 HF and is the answer not in the manual?

Siemens TM SIWAREX WP351 HF Specifications

General IconGeneral
BrandSiemens
ModelTM SIWAREX WP351 HF
CategoryControl Unit
LanguageEnglish

Related product manuals