Stability 1 applies to dosing steps 0, 1, 5, and 6;
Stability 2 applies to the remaining dosing steps 2 to 4.
ෙW
V
ෙG
V
:HLJKWSURJUHVVLRQ
ෙW
V
6WDELOLW\WLPH
ෙG
V
6WDELOLW\ZHLJKW
6WDELOLW\VWDWXV
7LPH
Figure 6-8 Stability monitoring
Stability weight 1 [stabilityWeight1]
The parameter defines the permissible deviation (+/-) by which the weight is allowed to
fluctuate within the stability time to detect stability. The input is made in the unit of weight.
Stability time 1 (s) [stabilityTime1]
This parameter defines the time window in which the current weight value may fluctuate within
the stability weight (+/-) to report stability.
Maximum waiting time for stability 1 (s) [maximumWaitingTimeStability1]
Defines a maximum waiting time for stability on start of a command which depends on stability.
If the command could not be started during the waiting time due to a lack of stability, a
technology message is generated by the electronic weighing system. If the parameter is set to
0 , a data/operating error is directly reported in the event of a lack of stability.
Delay time before stability 1 (s) [delayTimeBeforeStability1]
Defines a delay time which expires before a check for stability is performed.
Parameter assignment/addressing
6.5 DR03 Calibration parameters
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 67

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens TM SIWAREX WP351 HF and is the answer not in the manual?

Siemens TM SIWAREX WP351 HF Specifications

General IconGeneral
BrandSiemens
ModelTM SIWAREX WP351 HF
CategoryControl Unit
LanguageEnglish

Related product manuals