6.20.5 Weighing start options [startOptions] .....................................................................................99
6.20.6 Cycle time for automatic zero setting (s) [cycleTimeAutomaticZeroSetting] ..........................99
6.20.7 Number of weighings without automatic taring/zero setting
[numberOfCyclesWithoutZeroSetting]....................................................................................99
6.20.8 Check stop [checkStopAfterStep0 to checkStopAfterStep7]..................................................99
6.20.9 Automatic discharging [dischargeMode] ..............................................................................100
6.20.10 Discharge time (s) [dischargeTime] .....................................................................................101
6.20.11 Maximum discharge time (s) [dischargeMonitoringTime].....................................................101
6.20.12 Discharge overlapping time [dischargeOverlappingTime]....................................................101
6.20.13 No. of optimized loadings (OIML R-107) [NumberOfOptimizedLoadings] ...........................101
6.20.14 Dosing signals......................................................................................................................102
6.20.15 Delete tare in weighing step 0 [deleteTareStep0] ................................................................102
6.21 DR28 Configuration of additional string for protocols...........................................................102
6.21.1 Log with additional string [addAdditionalText]......................................................................102
6.21.2 Log single loadings (OIML R-107) [logSingleLoadings] .......................................................103
6.22 DR29 Configuration of technology messages......................................................................103
6.23 DR30 Read out process state ..............................................................................................103
6.23.1 Overview ..............................................................................................................................103
6.23.2 Digits unfiltered (linearized) [unfilteredDigitsNotLin] ............................................................104
6.23.3 Digits filtered by F1 [filteredDigits1]......................................................................................104
6.23.4 Digits filtered by F2 [filteredDigits2]......................................................................................104
6.23.5 Digits filtered by F3 [filteredDigits3]......................................................................................104
6.23.6 Status DI.0, DI.1, DI.2 and CI.0 [statusDI0] [statusDI1] [statusDI2] [statusCI0]...................104
6.23.7 Status DQ.0, DQ.1 and DQ.2 [statusDQ0 to statusDQ2].....................................................104
6.23.8 Refresh counter [refreshcounter] .........................................................................................105
6.23.9 Current load cell signal voltage (mV) [loadCellSignalVoltage] .............................................105
6.23.10 Load cell impedance (Ohm) [loadCellImpedance] ...............................................................105
6.23.11 Current load cell SEN voltage (V) [loadCellSenseVoltage]..................................................105
6.23.12 Current fine weight [currentFineWeight]...............................................................................105
6.23.13 Current trailing weight [currentTrailingWeightFine] ..............................................................105
6.23.14 Tolerance limits (weight unit) [toleranceLimitTh2] [toleranceLimitTh1]
[toleranceLimitTl1] [toleranceLimitTl2] .................................................................................105
6.23.15 Gross process weight 1 [grossProcessWeight1], Net process weight 1
[netProcessWeight1], Tare process weight [tareProcessWeight] ........................................106
6.23.16 Gross weight [grossWeight], Net weight [netWeight], Tare weight [tareWeight]..................106
6.23.17 Gross/net weight x10 [netWeightX10]..................................................................................106
6.23.18 Gross process weight 2 [grossProcessWeight2], Net process weight 2
[netProcessWeight2] ............................................................................................................106
6.23.19 Last net process weight [lastNetProcessWeight], Last net weight [lastNetWeight] .............106
6.23.20 Totalizer 1 [totalizer1] and Totalizer 2 [totalizer2] ................................................................106
6.23.21 Youngest protocol ID [youngestLogId] .................................................................................106
6.23.22 Date & time ..........................................................................................................................107
6.23.23 Current dosing step [subDosingStep] ..................................................................................107
6.23.24 Number of dosings in continuous mode [dosingsInContinuousMode] .................................107
6.23.25 Difference set point / actual value [differenceSetPointActualValue] ....................................107
6.24 DR32 Read out error messages ..........................................................................................107
6.24.1 Overview ..............................................................................................................................107
6.24.2 Operating errors, technology messages, data/command errors ..........................................107
6.25 DR34 Weight indicator .........................................................................................................108
Table of contents
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 7