User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
partX.db_TYPE
log data files.
X
is a number (decimal format without a leading
zero) of data file the same as file number stored in
log.db_log_files
. The
TYPE
can
be:
raster
— samples interval,
samples
— samples data,
timestamp
— samples synchronization points,
main_log data format description
Contains informations about logging functionality. There can be following types of data:
const_dev_info
– information specific to this device.
logs
– data describing current and past logs stored on device. Formatted as follows:
log index,
index of logged group,
internal log name,
date when log was created,
date when log was ended or text "
NULL
" if log is one of the current log,
event_log
— reserved for future use,
dev_settings
— reserved for future use,
Log data format description
Contains information about specific log. There can be following types of data:
group_settings
— group settings of this log. This is one line in following format:
group index,
name,
date when this log was created,
date when this log was ended or text “
NULL
” if log is one of the current log,
log description,
base log period,
alternative log period,
log mode (1 — always, 2 — triggered by channel),
logical channel count in this group,
full group configuration file name,
channel index which is a base trigger or “-1” if there is no channel,
channel index which is an alternative trigger or “-1” if there is no channel,
log_files
— information about all samples files created in this log in following format:
ID/file number,
file creation date,
file end date or text “
NULL
” if file is being currently used,
chan_conf
— settings of all channels that are being logged in following format:
channel index,
name,
selected data source index (see
Mode
parameter in
Chapter 7.8.1. Logical
Channels - General settings
),
unit channel unit or if there is no unit available
none
(translated into current
device language) label,
format index (see
Format
parameter in
Chapter 7.8.1. Logical Channels -
General settings
),
ON label,
OFF label,
287