- MPT Pick up Solenoid
- Duplex Solenoid
To run the solenoid test:
1. Select Device Test from Diagnosis Mode.
2. Select Solenoid Test. (Entering solenoid test mode completed and start test)
When solenoid test starts, 3 solenoids listed above are turned on at the same time. And turned off after 2
seconds.
Quality Pages(Print Quality Page
To print the print quality page:
1. Select PRINT TESTS from Diagnosis Mode.
2. Select Quality Pages.
2 pages will be printed. Button operations will be ignored until pages are printed.
First page is a skew adjusting page and the other page is a print quality checking page.
Page Count
You can check and modify the page count value.
To modify the page count:
1. Select Page Count from PRINTER SETUP menu.
2. The selected number can be increased or decreased with arrow keys and pressing Select will
apply the changed value temporarily.
3. Pressing Select again will save the changed number.
4. To cancel, press Return key.