11. System configuration
Pump settings => Pump settings => Lube Control => Pump Output
Step Key Display Description
Lube Control Entry and monitoring of the lubrication system are done in this menu
3
Press <OK control key>
)The following settings are available:
o Pump Output - Entry of the pump-specific parameters
o Pump Sensor Setting - Setting for the sensor between pump and zone valve
o Remote Manual Lube - Setting for the Input Type for remote manual lube
Pump Output The type of pump output for the active pump and for the redundant pump is specified in this menu
3.1
Use <OK control key> to select Pump Output
) You will enter the Pump Output menu
Use<down/up arrow key> to select Output Type: Select normally open, normally
closed, or disabled
Press <Save control key>
Use<down arrow key> and <Select control key> to enter Output No.
)Entering the output No. specifies the controller terminal of the pump motor.
Press <Select control key>
Use<down/up arrow key> to enter the output number
Press <OK control key>
Repeat the procedure for the following output type 2, redundant pump
Press <Back control key>
Lube Control
Output Pump
Sensor at Pump Set.
Remote Manual Lube
Output Pump
Output Type
[normally open ]
Output No.
[1.01 ] 0
Output Type 2 Redundant Pump
[normally open ]
Output No.
[1.01 ] 0
SelectBack
Back
Ok
EN
108