6. Configuration by operator/local admin
System design, Fig. 28
(pump motor,
max. 8 amp)
X4, 07
„p“ digital
MM
„p“ analog
„p“ analog
EM U3/2
EM U3/1
Verteiler VSL
Verteiler VSL2
KD
KD
I1.1
I1.2
I1.6
ZPU02 Pumpe
300bar
Ø 1 /Ø2 / Ø3
I 1.3 / I 1.4 / I1.5
I 1.7
LL = I 1.8
Ø 7
Ø4 /Ø5 / Ø6
I 2.4 / I 2.5 / I2.6
I 2.1
I 2.3
I 2.2
Monitoring zone 1 analog pressure switches
I 1.1 Main line 1
I 1.2 Main line 2
I 1.6 Feeder monitoring (piston detector)
Monitoring zone 2 analog pressure switches
I 2.1 Main line 1
I 2. 2 Main line 2
I 2.3 Feeder monitoring (piston detector)