(6) Press Adjust to switch to calibrate mode. Press and hold the OK button for several seconds until it and the
arrows around it turn red:
(7) Press Start. The test shape, which is a grid of 6 lines, will be drawn on the paper and the camera will move
over the test shape, take a photo, and display the photo on the control panel. If you cannot see the test
shape clearly, press the LED button once so that it reads LED 50% and press the Get PIC button. You
should see three items in the photo: the test shape that was drawn with the pen, a red +, and the blue
dashed +:
Retake photo
Update blue dashed + alignment
This is where photo
will be displayed
Change brightness of LED light
Adjust is calibrate mode
Two different screens based
on Align versus Adjust
Magnify photo by 300%
Align is normal mode
1. Select Adjust
2. Press and hold OK
3. Release after
buttons turn red
4. Press Start