EasyManua.ls Logo

SpectraLink IP-DECT SERVER 6500 - Page 195

SpectraLink IP-DECT SERVER 6500
456 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14215700-IG, Edition 15.0
May 2020, Original document
195
To define system wide settings:
1. Click Configuration, and then click Wireless Server.
2. On the Wireless Server configuration page, under Base stations, set the desired syn-
chronization options in Default sync type, LAN sync transport protocol and LAN sync
type of service:
Field
Wireless Server Configuration - DECT
Subscription allowed (Optional) If enabled, it is possible to subscribe new handsets to
the system.
Note: Subscription will be disallowed after 120
seconds or when a subscription succeeds. If more
time is needed or more handsets must be subscribed,
it is necessary to disable the parameter Auto-
matically disable subscription allowed below.
Automatically disable subscription
allowed (Optional)
If enabled, subscriptions will automatically be dis-
allowed after 120 seconds or when a subscription suc-
ceeds.
If disabled, subscriptions will be allowed until explicitly
disabled.
Default value: Enabled
Note: This feature is part of DECT Security Step A.
Authenticate calls (Optional) If enabled, each individual DECT call will be authen-
ticated.
Encrypt voice/data (Optional) Encryption of voice/data packets transmitted via
DECT.
Possible values: Disabled, Enabled or Required.
Default value: Required
Note: Repeaters do not support encryption. If set to
Required, the call is ended when handover is estab-
lished on the repeater.
Spectralink IP-DECT Server 200/400/6500 and Virtual IP-DECT Server One Installation and Configuration Guide