EasyManua.ls Logo

SpectraLink IP-DECT SERVER 6500 - Administration - Base Station - Base Station

SpectraLink IP-DECT SERVER 6500
456 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14215700-IG, Edition 15.0
May 2020, Original document
411
Administration - Base Station - Base Station
Field
Base Station - General
IP address (Read only) Current IP address of the base station.
Description (Optional) Enter a description.
It is recommended to use a description of the physical loc-
ation.
RPN Radio Part Number of the base station.
Note: If using zone based paging, assigning base stations
and RPN's are essential, as the RPN decides which zone the
Spectralink IP-DECT Base Station will be part of. For more
information, see "Example of Defining Sites, Zones and
Assigning Numbers to Base Stations" on page163.
If using radio based synchronization in connection with zone
based paging, RPN's must be assigned to the relevant zones
before defining synchronization chain.
Site Default value: None
It is possible to define sites for devices that are located at the
same location.
To assign a site to the base station, select the relevant site
from the list.
For information about defining sites, see "Defining a Site for
the Media Resource and Base Stations" on page177.
Disabled (Optional) If enabled, the base station will be disabled.
Note: If Add new as active is enabled (Configuration >
Wireless Server > Base stations), then this will be unset
by default when adding a new base station.
TX power (Optional) Used for controlling the output power for this specific base
station.
Select another value from the list, if you need to change the
output power.
Default value: Default (250 mW). If Frequency is set to USA,
the default value is 100 mW.
Note: If a system TX power other than default is set for the
whole system (Configuration > Wireless Server > DECT),
that setting will override this setting.
Spectralink IP-DECT Server 200/400/6500 and Virtual IP-DECT Server One Installation and Configuration Guide