EasyManua.ls Logo

SpectraLink IP-DECT SERVER 6500 - Page 298

SpectraLink IP-DECT SERVER 6500
456 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14215700-IG, Edition 15.0
May 2020, Original document
298
Field Setting
Redundancy Configuration - Settings
Failover time(sec) Enter value for failover time.
Failure time is the time in seconds from the Spectralink
IP-DECT/Virtual IP-DECT Server detects a failure, until
it initiates a failover operation and cause the other peer to
take over.
Default value: 15 sec
For more information about failure time, see "Failover
time conditions" on page304.
4. Click Save.
Note:
Enabling or disabling the reduncancy funtion on a given server, will not require a
reboot of the Spectralink IP-DECT/Virtual IP-DECT Server(s).
But, after clicking Save, all active calls can be dropped on base stations and media
resources when the function is enabled/disabled as all media resources and base
stations reconnect to the new setup.
Spectralink IP-DECT Server 200/400/6500 and Virtual IP-DECT Server One Installation and Configuration Guide

Table of Contents

Other manuals for SpectraLink IP-DECT SERVER 6500

Related product manuals