2.12.7 Brake management
CONFIGURATION FREQ. INVERTER BRAKE
STARTUP ADJUST
Startup adjustment of the brake
Press « ENTER » to go in the menu
STOP ADJUST
Stopping adjustment of the brake
Press « ENTER » to go in the menu
CONFIGURATION FREQ. INVERTER BRAKE STARTUP ADJUST
RELEASE TIME
Brake release time delay (brt)
[0.. 5] seconds (1 sec by default)
RELEASE FREQ.
Brake release frequency threshold (bIr)
Only in ASYNC OL
[0,0.. 10,0] Hertz (0,1 Hertz by default)
RELEASE CURRENT
Brake release current ( Ibr)
Brake release current threshold for Ascending or Forward movement.
[-100.. 100] Amperes (-0,1A by default for SYNC 0 A for ASYNC)
CONFIGURATION FREQ. INVERTER BRAKE STOP ADJUST
ENGAGE FREQ.
Brake engage frequency threshold (bEn)
Only in ASYNC OL
[0,0.. 10,0] Hertz
ENGAGE DELAY
Brake engage delay (tbE)
Time delay before request to engage brake. To delay brake engagement, if you wish
the brake to be engaged when the drive comes to a complete stop.
[0,00..5,00] seconds
ENGAGE TIME
Brake engage time (bEt)
[0,00..5,00] seconds