USER MANUAL « ASP 116 EVOLUTION »
Sprinte SAS, All rights reserved, including translation rights
2.12.7 Brake management
CONFIGURATION ► FREQ. INVERTER ► BRAKE
Startup adjustment of the brake
Press « ENTER » to go in the menu
Stopping adjustment of the brake
Press « ENTER » to go in the menu
CONFIGURATION ► FREQ. INVERTER ► BRAKE► STARTUP ADJUST
Brake release time delay (brt)
[0.. 5] seconds (1 sec by default)
Brake release frequency threshold (bIr)
[0,0.. 10,0] Hertz (0,1 Hertz by default)
Brake release current ( Ibr)
Brake release current threshold for Ascending or Forward movement.
[-100.. 100] Amperes (-0,1A by default for SYNC 0 A for ASYNC)
CONFIGURATION ► FREQ. INVERTER ► BRAKE ► STOP ADJUST
Brake engage frequency threshold (bEn)
Time delay before request to engage brake. To delay brake engagement, if you wish
the brake to be engaged when the drive comes to a complete stop.