2.15 Building
SETUP ► BUILDING
Number of levels served by lift
[2..32] Adjustable from 2 to 32 level
On Collective, the landing buttons below the main level are “up land” and the other
landing buttons “down land”. The car goes back to main level in case of fire operation
[0..31] This setting is reset to zero if it is higher than the numbers of levels.
Management of gaps levels for bank of lifts (multiplex)
.
The elevator that going down to the lowest level will have GAPS LEVELS = 0.
Other lifts that can not going down to the lowest level indicates the number of levels
they cannot serve with this parameter.
Example of a duplex:
The elevator that has 3 subsoil has GAPS LEVELS = 0
The elevator that has 1 subsoil has GAPS LEVELS = 2
The levels of the landings buttons are configured by referring to the elevator coming
down the lowest.
Levels of the car buttons are configured as a simplex
Return to a dedicated floor after a waiting time
Waiting time before the car returns to its stopped floor
Level of the stopped floor
In hydraulic, the stopped floor is obligatory the lowest.
Level of the ‘Out of Use’ operation
When this operation is activated , the lift will park at this floor.
Parking doors opened in ‘Out Of Use’ operation
Detection time of a blocked lift
Maximum time limit for taking calls into account. If the lift has calls waiting and the time
expires, then the lift is put into blocked state.
In this state, car sending and landing calls in progress are erased to warn the users
that the car will not be coming. In multiplex, is excluded from the bank. If the cause of
the blocking disappears and a new call is made, this will be responded to.
[1..20] minutes (4 minutes by default)