2.16 User operation
CONFIGURATION ► OPERATIONS
[UNIVERSAL] [UP OR DOWN] [FULL COLLECTIVE]
Erase the up and down floor button
Erase the up and down floor button when the car arrives at the level
Reduction of the parking temporization
If this option is "YES" pressing a button in the cabin shortens the delay of parking and
improves the performance of the elevator in buildings with low traffic.
Time during which the car remains lit up when the lift is in an available state
Car priority timer
A user in the car must have a minimum of 2 secs after the doors close to select his
destination (5.12.4.2 EN 81-20).
Operation during timer duration:
In collective operation, if no movement direction is assigned, the user in the car has
priority on the next destination.
In blocking operation, the landing buttons indicate car occupation and the user in the
car has priority on the next destination.
This key in the car reserves the lift for car calls, landing calls are suspended.
“series 1” PE3M-CCC / 216SP “series 2” CB9-CCC / 211SP
Priority call for firemen
Enables rapid intervention by fireman, brings the car to priority level.
Input TR1M-CPO / 216SP
Car call level in case of firemen priority call
Minimum time to return to normal mode after exiting inspection mode. This time is a
safety measure, it enables leaving the technician time to exit the car roof before the lift
goes back into normal mode
[10..120] seconds (10 seconds par default)
Inspection movement beyond the end decelerator
Select here whether you want to forbid the inspection movement beyond the end
decelerators (top and bottom)
[MOVEMENT ALLOW.] [MOVEMENT FORBID.]