USER MANUAL « ASP 116 EVOLUTION »
CONFIGURATION
Sprinte SAS, All rights reserved, including translation rights
35
HWAY.ACC.DETECT
Hoistway access detection
The hoistway access detection sets the lift out of order(“HOISTWAY ACCESS” fault,
see 4.4.11), in the case a landing door has been detected opened for longer than 8
seconds (thanks to the landing doors safety locking contact), out of a normal car
parking in user mode. The presence of a technician is mandatory to set back the lift in
user mode.
This detection only occurs in user mode
Caution : this detection can’t operate properly with a lift compliant to EN81-20 standard
, as in that case the landing doors are always unlocked when the lift is idle in user
mode.